Smartphone-Based Deep Learning Exophthalmometry in Thyroid Eye Disease: A Multicenter, Multiethnic Validation Study.
Wednesday, October 7, 2026
Published in Thyroid : official journal of the American Thyroid Association. Abstract: Proptosis is the principal quantitative measure of disease severity in thyroid eye disease (TED), but Hertel exophthalmometry has substantial interobserver variability and requires in-person specialist visits. Existing deep learning (DL) proptosis-from-photograph models require studio-acquired images. We aimed to validate, in a multicenter multiethnic study, a DL model fine-tuned to estimate proptosis (mm) from nonstudio facial photographs-smartphone selfies or clinician-taken photographs. This validation study included 361 patients with confirmed or suspected TED at three institutions. Data were collected prospectively at two Korean sites-Severance Hospital (SH; 203 patients/3654 facial images; internal validation) and Seoul National University Bundang Hospital (SNUBH; 79/933; same-ethnicity external validation)-and retrospectively, from routine-care images, at one Spanish site, Virgen Macarena University Hospital (HUVM; 79/336; different-ethnicity external validation). Korean patients self-acquired selfies on six smartphone models per site using a capture-guidance application; Spanish images were clinician-acquired during routine care without such guidance. The model-a dual-stream ResNet-18 jointly processing a facial image and a per-pixel depth map (ZoeDepth)-outputs a proptosis estimate (mm) per eye from one photograph and was fine-tuned, from a previously published model trained on studio digital single-lens reflex photographs, for these nonstudio acquisitions. Hertel me...
5 Key Takeaways
- Mean absolute error versus Hertel measurement was 1.14 mm in Severance Hospital internal validation.
- Mean absolute error versus Hertel measurement was 1.44 mm in Seoul National University Bundang Hospital same-ethnicity external validation.
- Mean absolute error versus Hertel measurement was 1.58 mm in Virgen Macarena University Hospital different-ethnicity external validation.
- Predictions were within 2 mm of Hertel in 83.6% of images at Severance Hospital.
- Area under the receiver operating characteristic curve for detecting severe proptosis (Hertel ≥21 mm) was 0.94 in Severance Hospital.
OpenRounds transcript synthesis · Verify against the source
Daily healthcare AI brief
Get the free healthcare AI briefing
One concise briefing built from reporting, research, policy, blogs, videos, and full podcast transcripts.
Free. Get a sign-in link by email to finish subscribing. An account is created if needed. Unsubscribe anytime. Already subscribed? Sign in to save and personalize.