Back to OpenRounds
PubMedEuropean spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society

Digital twin validation and predictive value of delta radiomics based on tabular transformer for synergistic muscle imbalance in lumbar disc degeneration.

Thursday, October 8, 2026

Referenced in Daily Briefing

Published in European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society. Abstract: Current methods struggle to quantify muscle synergistic imbalance and nonlinear interactions in Lumbar Intervertebral Disc Degeneration (LIDD). This study proposes a novel strategy combining "Delta Radiomics" with a Tabular Transformer deep learning architecture, aiming to improve the precision of early risk assessment. A retrospective analysis was conducted on L4-L5 MRI images from 663 subjects. Texture features of the Psoas Major (PM) and Erector Spinae (ES) were extracted, and (PM-ES)/ES was calculated as the "Delta Feature" to eliminate individual variation. An in silico digital twin simulation system was constructed to validate the physical sensitivity of these features. The predictive performance of the nonlinear Tabular Transformer model was compared with a traditional logistic regression model. In silico experiments confirmed that Delta features possess superior "common-mode noise rejection" capabilities. In the early stage of degeneration (Step 20), when original features showed only weak changes, Delta features detected highly significant inter-group differences (P < 0.001). In the independent test set, the Tabular Transformer model demonstrated the best discriminative power with an AUC of 0.848 (95% CI: 0.781-0.916), outperforming the Combined linear model utilizing the same features (AUC = 0.804, P = 0.089) and single-modality models. Although the raw AUC improvement was marginal, Decision Curve Analysis (DCA) and quantitative calibration (Brier score = 0.145) sho...

Read Source ↗

OpenRounds Source Analysis

Sign in for an evidence-focused interpretation, plus Saved articles and your personalized feed.

Sign InBack to OpenRounds

Daily healthcare AI brief

Get the free healthcare AI briefing

One concise briefing built from reporting, research, policy, blogs, videos, and full podcast transcripts.

Free. Sign in to subscribe. Unsubscribe anytime. Already subscribed? Sign in to save and personalize.